• <tr id='iNB5Nn'><strong id='iNB5Nn'></strong><small id='iNB5Nn'></small><button id='iNB5Nn'></button><li id='iNB5Nn'><noscript id='iNB5Nn'><big id='iNB5Nn'></big><dt id='iNB5Nn'></dt></noscript></li></tr><ol id='iNB5Nn'><option id='iNB5Nn'><table id='iNB5Nn'><blockquote id='iNB5Nn'><tbody id='iNB5Nn'></tbody></blockquote></table></option></ol><u id='iNB5Nn'></u><kbd id='iNB5Nn'><kbd id='iNB5Nn'></kbd></kbd>

    <code id='iNB5Nn'><strong id='iNB5Nn'></strong></code>

    <fieldset id='iNB5Nn'></fieldset>
          <span id='iNB5Nn'></span>

              <ins id='iNB5Nn'></ins>
              <acronym id='iNB5Nn'><em id='iNB5Nn'></em><td id='iNB5Nn'><div id='iNB5Nn'></div></td></acronym><address id='iNB5Nn'><big id='iNB5Nn'><big id='iNB5Nn'></big><legend id='iNB5Nn'></legend></big></address>

              <i id='iNB5Nn'><div id='iNB5Nn'><ins id='iNB5Nn'></ins></div></i>
              <i id='iNB5Nn'></i>
            1. <dl id='iNB5Nn'></dl>
              1. <blockquote id='iNB5Nn'><q id='iNB5Nn'><noscript id='iNB5Nn'></noscript><dt id='iNB5Nn'></dt></q></blockquote><noframes id='iNB5Nn'><i id='iNB5Nn'></i>
                欢迎莅临众购彩!
                服务热线 400-602-0999
                低气压试验
                众购彩的低气压试验箱,温↓度范围覆盖-70℃至150℃,气压范围覆盖0.2kPa至101kPa要用于考核航空航天装备、电子元器件或@ 者其他产品在低气压、温湿度综合作用下的☆可靠性,可开展低ξ 气压试验、高温低气压、低温低气压、快速减压试验等试验项目。
                服务介绍
                低气压试验,是用设备模拟高空气压环境,用来确定元件、设备或其他产品在低气压条件下贮存、运输或使♀用的适应性。
                众购彩有多套低气压试验箱,可开♂展单纯低气压实验,低气压-温度综合试验,低压气-温度-湿度综※合试验。
                 

                资质能力:

                通过CNAS认可,CMA认可。
                 

                适用范围:

                可为电子、仪器仪表、汽车以及航天产品的元器件、结构件、组件以及整机等开展低气压试验。
                 

                测试标准:

                GB2423.27-2005,IEC60068-2-39-1976,GB2423.42-1995,GB2423.102-1995,GB2423.26-2008,IEC60068-2-41-1976,GB2423.21-2008,IEC60068-2-13-1983等。
                 

                试验项目:

                1.单纯低气压实验。
                在试〓一下中应保持下列压力,其允许差未↘±5%或±0.1kPa(以〗大者为准),在84kPa等级时的允¤差为★±2kPa。如下表所示。
                气压 试验气⊙压允差 近似海拔高度(h)
                kPa mbar kPa mbar
                1 10 ±0.1 ±1 31200
                2 20 26600
                4 40 ±5% 22100
                8 80 17600
                15 150 13600
                25 250 10400
                40 400 ±2 ±20 7200
                55 550 4850
                61.5 615 4000
                70 700 3000
                79.5 795 2000
                84 84 /
                 
                2.低气压-温度综合试验
                表1 温度、气压和持续时间的优选组合
                温度(℃) 气压 持续时间(h)
                kPa mbar
                155 4 40 2
                85 4 40 2
                155 15 150 2
                85 15 150 2
                55 15 150 2
                55 25 250 2
                55 40 40 2
                55 55 550 2;16
                55 70 700 2;16
                40 55 550 2

                 

                3.低气压-温度-湿度综合试验

                温度-湿度-高度试验条件及步骤如下:

                a) 在实验室正常大气条件下对受试样品进行初始∮检测;

                b) 受试样品断电,将其放入试验箱内,尽可能模拟其实际安装使用状态;

                c) 变化到冷/干——受试样品不工作①,在40min内调节试验箱的温度从室温降至①-55℃;

                d) 冷/干  浸泡——受试样品不工作,使受试▆样品在温度为-55℃的条件下保持4h;

                e) 冷/干  温升——以最低工作电压18VDC给受试样品通电使其工作,然后在10min内将试验箱内温度升至-40℃;

                f) 冷/干  性能检查——完成步骤e)后立即观察≡测试软件界面是否有故障出现;

                g) 变化到冷/干  高度——保持受试样品工作状态,在10min内将试验箱≡的压力由实验室压力降低到41.06kPa(对应高度为7000m);

                h) 冷/干  高度——保持试ㄨ验箱内温度-40℃和压力41.06kPa的条件30min;

                i) 变化到温/湿——在1h内将试验箱内的温度升高到32℃,压力升至实验室压力,从不控制湿◣度变为相对湿度到95%;j) 温/湿  保持——保持试验箱内温度32℃、实验室气∩压和相对湿度95%的条件30min;

                k) 变化到热/干——将电源电压调整为30VDC,在1h内将试验箱ㄨ内温度升高到最高工作温度70℃,相对湿度降低到25%;

                l) 热/干  浸泡——保持试验箱内温度70℃和相对湿度25%的条件2h;

                m) 热/干  性能检查——完成步骤l)后立即观察测试软件界面是否有故障出现;

                n) 变化到热/干  高度——在10min将试验箱内的压力由实验室压力降低到41.06kPa;

                o) 热/干  高度——保持试验箱内温度70℃、压力41.06kPa和相对湿度25%的条件4h;

                p) 热/干高度  性能检查——完成步骤o)后立即观察测试软件界面是否有故障出现;

                q) 变化到实验室环境条件——在30min内将试验箱温度从70℃、压力从41.06kPa,恢复到实验室正常大气条件,不控制湿度,变化结束后,受试样ζ 品停止工作;

                r) 步骤c)~步骤q)为一个ζ 完整的循环,试验共进行10个循环;

                s) 10个循环试验结束后〇,使受试样品在实验室正常大气条件下恢复至稳定状态后对其进行最终检测。

                 

                照片:

                  

                图1 低气压-温度综合试验箱外观                                   图2 低气压-温度-湿度综合试验箱外观